I have created this climate:
- name: "Riscaldamento"
unique_id: "termostato"
modes:
- "off"
- "heat"
- "cool"
mode_command_topic: "home/riscaldamento_raffrescamento/TEST/mode/set"
mode_state_topic: "home/riscaldamento_raffrescamento/TEST/mode/state"
temperature_command_topic: "home/riscaldamento_raffrescamento/TEST/temp/set"
current_temperature_topic: "home/riscaldamento_raffrescamento/TEST/temp/state"
power_command_topic: "home/riscaldamento_raffrescamento/TEST/pump/set"
payload_on: 1
payload_off: 0
min_temp: 17
max_temp: 28
temp_step: 0.1
precision: 0.1
thinking that the power_command_topic would be sent whenever the temperature would go over/under the one set, but nothing ever get send to that topic. How can I turn on the pump when the temperature goes under the one set and turn it off when it goes over?
I’m trying to use the generic thermostat:
climate: - platform: generic_thermostat name: termostato_raffreddamento heater: switch.valvola_climatizzazione target_sensor: sensor.aqara_temp_sala_temperature min_temp: 24 max_temp: 28 ac_mode: true target_temp: 26 cold_tolerance: 0.1 hot_tolerance: 0.1 min_cycle_duration: seconds: 300 keep_alive: minutes: 3 initial_hvac_mode: "off" away_temp: 28 precision: 0.1
But I only have the button to turn it off:
If I click it nothing happens. What have I done wrong?
I remove the feature “Climate HVAC mode” and added it again and now I can use it.